Setup guide

Dedicated Micros ©2007
23
BX2
NOTE: The IP address used to dial in to the unit is the IP address used for PPP_Link2.The PPP IP address
used in System Options->Network Settings->PPP Selection is the base PPP IP Address. The dial in
address is one greater than this. Ie if the PPP IP address is dened as “10.0.0.1”, the PPP IP address
required to connect to the unit is “10.0.0.2”.
The unit will request a username and password, as dened in the ‘proles’ conguration le. The default settings
are ‘username’ and ‘password’.
NOTE:
The Username and Password should be changed to maintain security. This is done by editing
the ‘proles’ conguration le on the unit. For full details on how to do this, see the Networking
Guide, which can be downlaoded from the unit’s web pages (See Operator Reference section)
Dial out
To make an outgoing PPP connection (to send an email), ensure the unit has been congured to send an email
under specic conditions, that the correct telephone number has been entered in the proles le, and that this
prole has been congured in the email settings. Email settings are congured using the embedded web pages
and the process is explained in the Networking guide..