Product data
[Project Number] [Project Name]
[Date] [Project Location]
28 10 00 19
Electronic Access Control/Intrusion Detection
2. The system administrator may assign one or all of these items to named groups. The system operator will
be able to select any/all of these items by selecting the name of the desired group, and perform system
functions in a ‘batch mode’ on all of them.
3. The system administrator may partition the system using Groups.
K. Access Group Templates:
1. The system administrator will be allowed to select any existing access group and use that group as a
template for creating a new similar access group.
L. Default Relay and Input Assignments:
1. The system shall provide default settings for relay and input assignments. This default programming will
be populated each time a reader is programmed.
2. The system shall allow the operator may choose to modify these default settings as required.
M. Import:
1. The system shall support importing of personnel data from other databases.
2. The system shall be capable of recognizing any flat file that contains ASCII data.
3. The operator will be able to select the field separation character.
N. Export:
1. The system shall support exporting of all system events. The operator will have the option of selectively
exporting any/all event record types.
O. Auto Import/Export:
1. The system shall support automatic import/ export of data to and from the ACS database. The system
operator may set up specific files to ‘import (from)’ or ‘export (to)’. These files may be on a local drive or
network drive.
P. Elevator Control:
1. The system shall be capable of controlling access to building elevators by making use of Access Groups
with no special controller being used.
Q. Archive and Restore of Data:
1. Data Archive:
a. The system shall allow archiving of the data required to configure the system. The operator will be
able to choose to archive all configuration data or, selectively back up this data by category.
b. The operator will be able to archive events as well. The entire Events data will be able to be
archived or, only select event types can be backed up based on a period of time.
c. The system shall offer the option of storing the archived events/configuration data in the local
database or, in a database present on a remote site.
d. The operator shall be capable of setting up archive database backups by a schedule for automatic
backups.
2. Data Restore:
a. The system shall allow restoration of all previously archived data. The operator will be able to
restore all configuration data or, restore only select data by category.
b. The system shall allow the administrator to restore data from any location where an archive was
previously done, and will still be available to the system via network connection.
R. Scheduled Changes:
1. The system shall be capable of scheduling time changes to Readers, Inputs, Relays and Links,
automatically. The system will be able to execute these scheduled changes without the need for operator
intervention.
2. The system also shall provide the operator the flexibility to control the scheduled change by a single
device or a ‘Group’ of devices.