User manual
V002450_25_CR1200-CR2-CR3-CR2500-CR3500_Interface_Configuration_Document_CLIENT.docx
2011-04-27 Page 34 of 65
© 2011 The Code Corporation
•
14870 S. Pony Express Rd., Suite 200, Bluffdale, UT 84065
•
(801) 495-2200
•
FAX (801) 495-0280
Reg
Setting Name
Default (hex)
Comment
71
Interleave 2 of 5 Checksum
(interleave2of5Checksum)
0
Binary Dip Switch
Bit
Controls
Value
0
Interleave 2 of 5 Checksum
Checking
0: Disable
1: Enable
1 Strip Checksum From Output
0: Disable
1: Enable
Also see registers: 6e, c9
72
Auto Stored Data Erase
(autoLogErase)
1
0: Disable
1: Enable
Note: When “1,” data and images are cleared from
nonvolatile memory when they are successfully uploaded to
the Host. (In “Log mode,” this is set to “0.”)
73
Auto Transfer Buffer
Memory (autoBufferUpload)
1
0: Disable
1: Enable
When “1,” the Reader will automatically upload buffered data
(i.e., storage that hasn’t been previously uploaded) whenever
a connection is present.
74
UPC Short Margin
(enableUpcShortMargin)
1
0: Disable
1: Enable
Also see registers: 4d, 4e, 6a
75
RS-232 Batch Mode
(uartAlwaysConnected)
0
0: Detect RS232 cable by presence of power on pin 1.
1: Assume RS232 cable is always connected
76
Storage Mode
(sendAndStoreMode)
0
0: Normal mode (buffered send)
1: Send and log mode
3: Log only mode
Also see registers: 72, 73
78
Settings Lock
(settingsLock)
1
1: Settings unlocked
3: Settings locked (except settingsLock (78))
85
Trioptic Options
1
Binary Dip Switch
Bit
Controls
Value
0
Trioptic Decoding, Normal Quiet
Zones
0: Disable
1: Enable
1 Allow Short Quiet Zones
0: Disable
1: Enable
2
No Quiet Zones Required (requires
firmware version 3280+)
0: Disable
1: Enable
86
Motion Detection Event
(motionEvent)
0
Valid Range:
0: Disable
When motion is detected, this event is posted.
See register 39 for list of events.