Reg
Setting Name
Default (hex)
Comment
41
Text Commands
(commandOptions)
8
Binary Dip Switch
Bit
Controls
Value
0 Text Commands
0: Disable
1: Enable
1 Suppress Echo
0: Disable
1: Enable
2 Suppress Responses
0: Disable
1: Enable
3
Disable Text Commands but
Enable Magic Sequence; See
Below
0: Disable
1: Enable
4
Suppresss URL Decode; See
Below
0: Disable
1: Enable
5 Accept On Timeout
0: Disable
1: Enable
Magic Sequence:
The Magic Sequence is the string “;>PAx” where x is 1, 3, or
7 as defined above. This would normally be used in command
text files, which would begin with the text-command-on
sequence and end with the command to return to this special
mode. For example:
;>PA7
;any desired commands here
PA8
Note: ;>PAx is supported in firmware version 2210+
Additional settings in firmware version 3430+
Suppress URL Decode:
For example, if enabled, P%418 will not equal PA8.
The % is not recognized as an escape character
Accept On Timeout:
Note: See register 156 for details
42
Expect Acknowledgement
From Host
(commExpectResponse)
0
0: Reader doesn’t wait for acknowledge
1: Reader will retransmit data when Host doesn’t
acknowledge receipt
43
JPEG Picture Quality
(jpegQuality_percent)
32
(#50)
Valid Range: 0 to 64 (#100) Percent
0: Raw Image (No JPEG Compression)
1 To 100: JPEG Compression Quality Percent
Also see registers: 36, ab, ac, ad, ae, af, b1