User manual

V002450_25_CR1200-CR2-CR3-CR2500-CR3500_Interface_Configuration_Document_CLIENT.docx
2011-04-27 Page 28 of 65
© 2011 The Code Corporation
14870 S. Pony Express Rd., Suite 200, Bluffdale, UT 84065
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default (hex)
Comment
2c
Extra Time in Active Mode
When Cable is Connected
(extraCabledActiveTime_ms)
6DDD00
(#120*60*1000
(7200000 ms or 2
hours))
Valid Range: 0 to 7FFFFFFF Milliseconds
Active Mode is the time between the last user interaction with
the Reader (button press, etc.) and Power-Saving Idle Mode.
This setting increases Active Mode time only when the
Reader is cabled.
Power Usage: 4 out of 4
Next state: Idle
Note: in “continuous read” mode, this is also the continuous
read timeout period.
Also see registers: 32, 88, 8e, 9e, 9f
2d
Keyboard Maps
(kbMap)
0
0: US English (without leading 0 in the alt _ Num)
1: ASCII (alt+number) - universal
2: Custom (requires user to download keyboard map)
3: US English (with leading 0 in the alt + num for non-
printable ASCII)
4: French Keyboard
5: German Keyboard
6: Japanese Keyboard
7: US English (with ctrl + char for non-printable ASCII)
Note: Supported in firmware version 2394+
Note: These settings will not be reset by factory defaults
32
Time in Active Mode
(activeTime_ms)
493E0
(#5*60*1000
(300000 ms or 5
minutes))
Valid Range: 0 to 7FFFFFFF Milliseconds.
Active Mode is the time between the last user interaction with
the Reader (button press, etc.) and Power-Saving Idle Mode.
Power Usage: 4 out of 4
Next state: Idle
Note: in “continuous read” mode, this is also the continuous
read timeout period.
Also see registers: 2c, 88, 8e, 9e, 9f
34
Maximum Candidate
Decodes Per Read
(maxStickyDecodes)
1
The Reader will process up to this number of codes per “read
code” event. If there are more than this many codes in the
field of view and within target tolerance, only the first ones
will be decoded. For fastest performance with single codes,
set to 1.
Also see register 44
35
Button Stay-Down Time
(stickyTime_ms)
0
Valid Range: 0 to 7FFFFFFF Milliseconds
Keep processing the “read code” events for this amount of
time (act as if the button sticks down for this time)