User manual
V002450_25_CR1200-CR2-CR3-CR2500-CR3500_Interface_Configuration_Document_CLIENT.docx
2011-04-27 Page 27 of 65
© 2011 The Code Corporation
•
14870 S. Pony Express Rd., Suite 200, Bluffdale, UT 84065
•
(801) 495-2200
•
FAX (801) 495-0280
Reg
Setting Name
Default (hex)
Comment
1c
Baud Rate (uartBaud)
E100
(# 57600)
All standard baud rates up #115200
• #9600 (2580)
• #19200 (4B00)
• #38400 (9600)
• #57600 (E100)
•
#115200 (1C200)
1d
Stop Bits (uartStopBits)
2
1: Send 1 stop bit
2: Send 2 stop bits
1e
Data Bits (uartDataBits)
8
7: 7 data bits
8: 8 data bits
22
Parity (uartParity)
0
0: None
1: Odd
2: Even
26
Beep/Vibrate Volume
(beepVolume_percent)
64
(#100)
Valid Range: 0 to 64 (#100) Percent
This is the percentage of full volume.
Also see registers: 59, a7
29
PDF417 Symbology
(enablePdf417)
1
0: Disable
1: Enable
Also see registers: 2a, cf
2a
Micro PDF417 Symbology
(enableMicroPdf417)
0
0: Disable
1: Enable
Also see registers: 29, cf
2b
QR Code Symbology
(enableQrCode)
0
Binary Dip Switch
Bit
Controls
Value
0 QR Code Decoding
0: Disable
1: Enable
1 Inverse QR Code Decoding
0: Disable
1: Enable
2 Micro QR Code Decoding
0: Disable
1: Enable
3 Inverse Micro QR Code Decoding
0: Disable
1: Enable
Note: Micro QR is supported in firmware version 2378+