User manual
V002450_25_CR1200-CR2-CR3-CR2500-CR3500_Interface_Configuration_Document_CLIENT.docx
2011-04-27 Page 26 of 65
© 2011 The Code Corporation
•
14870 S. Pony Express Rd., Suite 200, Bluffdale, UT 84065
•
(801) 495-2200
•
FAX (801) 495-0280
Reg
Setting Name
Default (hex)
Comment
1a
Straight 2 of 5 Symbology
(enableMiscBarcodes)
1
0: Disable
1: Enable
Straight 2 of 5 (with 2 or 3 start/stop codes ) Decoding
1b
Communications Mode
(commMode)
2
CR2/CR3:
0: PS/2 (AT) keyboard
1: RS232 serial
2: USB keyboard
3: Reserved
4: RF (Bluetooth
®
)
5: USB Native (HID)
6: USB VComm (3000+ firmware)
7: USB HID POS -Terminal 131 (firmware 3484+)
CR1200:
0: PS/2 (AT) keyboard (firmware 4126+ and serial number
10050561+)
1: RS232 serial
2: USB keyboard
3: Reserved
4: Not valid
5: USB Native (HID)
6: USB VComm (3000+ firmware)
7: USB HID POS -Terminal 131 (firmware 4144+)
This setting is used in conjunction with settings 08 and 42 to
configure the communication mode between standard “one-
way” and “two-way” modes.
For example, USB “two–way” native:
1b: 5 (USB Native)
08: 2 (packet mode)
42: 1 (expect response)
Note: The following must be completed within 1 second.
first output report with numlock set and capslock clear
second output report with numlock set and capslock clear
third output report with capslock set numlock clear
fourth output report with capslock set numlock clear
fifth output report with numlock set and capslock clear
sixth output report with numlock set and capslock clear
On the last output report comm protocol is set to raw mode,
comm expect response is false and comm mode is USB
Downloader mode
Note: In firmware 3550+ register 78 also disables this feature.
CR1200 enables this in 4245+
Note: PS/2 is not supported on the Embedded CR1200