Instruction manual
1Error list
Error no. H7840
1-31
H7840 Error message MXT/MXS command Illegal received data
Cause The command argument and the data type do not match.
Measures Check the command and the data you are sending.
H7901 Error message OPTION1#1 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7902 * Error message OPTION1#2 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7903 Error message OPTION1#3 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7911 Error message OPTION2#1 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7912 Error message OPTION2#2 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7913 Error message OPTION2#3 Parameter illgal
Cause Correct the parameters.
Measures Correct the parameters, and then turn the power ON again.
H7920 * Error message Three EX-SIO Cards are installed
Cause This card can install one or two.
Measures Reduce these interface cards to one or two.
H7930 * Error message Illegal OPTION Slot No.(EX-SIO)
Cause EX-SIO Card is installed SLOT3.
Measures Install Expantion Sirial Card in SLOT1/2.
H7990 * Error message OptionCard illgal insert
Cause Check SLOT number
Measures Turn the power OFF, and then change the slot to mount it.
H8015 * Error message Plural Vision I/F are installed
Cause This card can install one.
Measures Use only one of these interface cards.
H8201 Error message Illegal param (TPTMMG)
Cause The TPTMMG parameter setting is illegal.
Measures Correct the TPTMMG parameter.
H8202 Error message Illegal param (TPERRNO)
Cause The TPERRNO parameter setting is illegal.
Measures Correct the TPERRNO parameter.
H8203 Error message Illegal param (TPSIGNO)
Cause The TPSIGNO parameter setting is illegal.
Measures Correct the TPSIGNO parameter.
H8204 Error message Illegal param (TRAP)
Cause The TRAP parameter setting is illegal.
Measures Correct the TRAP parameter.
H8206 Error message Failed in initialization (trap function)
Cause Failed in initialization (trap function)
Measures Turn the power OFF and ON once. When it comes back, contact to the dealer.
Error No. Error cause and measures