Instruction manual

1Error list
Error no. L3300
1-19
L3300 Error message User slot cannot be executed
Cause A user slot cannot be executed.
Measures Check whether the system slot is being operated.
L3310 Error message Cannot execute XRUN (Runing)
Cause XRUN is not possible as the designated slot is operating.
Measures Stop the specification slot, and execute.
L3320 Error message Cannnot execute XRUN (empty)
Cause XRUN is not possible as the program has not been selected.
Measures Specify program name to the argument or execute XLOAD.
L3330 Error message Cannnot execute XSTP (empty)
Cause XSTP is not possible as the program has not been selected.
Measures correct the program, and execute.
L3340 Error message Cannnot execute XRST (empty)
Cause XRST is not possible as the program has not been selected.
Measures Resetting is possible in the state of waiting only.
L3350 Error message Cannnot execute XRST (Running)
Cause XRST is not possible as the program is executing.
Measures Stop execution, and do it.
L3360 Error message Cannnot execute XLOAD (not PSA)
Cause XLOAD cannot be executed when the program cannot be selected.
Measures Execute XRST, and do it.
L3361 Error message Can not load the program(SLT*)
Cause A non-existing program was specified in the slot parameter (SLTn).
Measures A non-existing program was specified in the slot parameter (SLTn).
L3370 Error message Cannnot execute XCLR (empty)
Cause XCLR is not possible as the program has not been selected.
Measures XCLR can only be executed to enable program selection.
L3380 Error message Cannnot execute XCLR (not PSA)
Cause Program selection is not enabled.
Measures Execute XCLR after resetting the program (canceling the abort status).
L3390 Error message Cannot use arc pallet
Cause Cannot use arc pallet.
Measures Change to another method.
L3400 Error message System error (PROC stack over)
Cause System error. (Processor stack overflow. )
Measures When it comes back, contact to the dealer
L3500 Error message Ilegal format input (INPUT)
Cause The type of the variable specified by INPUT and the type of the received data do not match.
Measures Check the format.
L3600 Error message Jump destination does not exist
Cause No jump destination was found for the DEF ACT, ON COM and ON GOTO commands.
Measures Check the jump destination.
L3700 Error message Undefined variable
Cause It was attempted to reference a variable that has not been initialized.
Measures Define a variable, enter an initial value, and then use it.
L3710 Error message Nesting over (CALLP)
Cause Program CALL is used more than the limitation.
Measures Reduce the call count of CALLP (nesting).
Error No. Error cause and measures