Owner's Manual
Table Of Contents
3
LT
BLUE FACTORY ARM I
PULSE AFTER START ( - )
This wire will supply a ( - ) 200mA pulse both upon arming the system and upon
successful completion
of
the remote start activation sequence and is typically used to
re-lock the vehicle's doors upon remote start if necessary.
This output
is
configurable
in
option programming.
4
LT
GREEN/BLACK FACTORY DISARM I
PULSE BEFORE START ( - )
This wire will supply a ( - ) 200mA pulse both upon disarming the system and when
the remote start feature
is
activated. Locate the factory perimeter alarm disarm wire
from the key cylinder inside the drivers door.
Verification: This wire registers ground if the key is turned to the unlock
position
in
the driver's door cylinder.
This output is configurable
in
option programming.
1 BLUE UNLOCK
(-)
2 GREEN
LOCK
(-)
The door lock I unlock outputs are designed to control several different types
of
systems which may require additional parts. Please review the wire and location
chart to see which type
of
door lock system is
in
your vehicle. The most common
types are shown in the following diagrams.
These wires supply a ( - ) 500mA output.
2014 Voxx Electronics Corporation. All rights reserved.
11