Technical data
-20-
Menu point F1, F2 – Adjustment of alarm functions (only visible at model CC28 DA)
1. Activate menu point F1 resp. F2.
2. The display reads the presently set code for the alarm function.
Display Alarm for exceeded threshold ...
N S
non-storing (= non-latching), not resettable (# at alarm 2)
S C
storing (= latching), resettable when fallen below
3. Use keys
ZERO
TEST
and
SPAN
INFO
for setting the parameter.
4. Press key
QUIT
MENU
briefly to leave menu point F1 resp. F2 .
5. If necessary, store the parameter (SAUE).
Note:
The buzzer function at model CC28 DA is fixed to: „Alarm for exceeded threshold, non-latching,
resettable even during existing alarm conditions“.
The EC-Type Examination Certificate BVS 05 ATEX G 001 X is valid at alarm 2 only if set to
„S C“ storing (=latching).
Menu point iNFo – Indication of sensor type (MK number), sensor serial number, software
version, serial number and code
1. Activate menu point iNFo.
2. One after the other the display reads the MK number (S.typ xxx), the sensor serial number
(S.nr xxxx), the software version (SoFT xxxx), the 8-digit serial number of the transmitter in
2 parts (F.nr
-
xxxx F.nr_ xxxx) and a code (CoDE xxxx).
The figure indicated as CoDE is a (only temprorarily valid) code, which allows the activation of the
zeropoint adjustment without any limitations (refer to Check and AutoCal Adjustment of Zeropoint).
Menu point ESC – Leaving the service menu without storing
1. Select menu point ESC.
1. 2. Press key
QUIT
MENU
briefly to leave the service menu without storing of parameter
changes.
Menu point SAUE – Leaving the service menu with with storing
1. Select menu point SAUE.
2. Press key
QUIT
MENU
briefly to leave the service menu with storing of parameter changes.
Notes:
When the type of gas is changed, confirming the menu point activates the storing immediately and
enables the parameters for this type of gas.
Apart from this exception you can change several parameters one after the other without storing in between.
One collective storing procedure at the end of the settings saves all parameters which have been changed in
the service menu.