Owner's Manual

4
-Trunk
Output
Timing - Red/White Output:
Control
of
the
RED/WHITE
trunk
release output wire when trunk release is activated from the transmitter.
1
Second
Pulse -
Single
1 second pulse.
1
0
Seconds -
Output
stays active
for 1
0
seconds regardless
of
length
button press on transmitter.
20 Seconds -
Output
stays active
for
20
seconds regardless
of
length
button press on transmitter.
Latched
untiiiGN
ON-
Output stays active until the ignition is turned on.
Latched ON
until Button Press -
Output stays active until deactivated by
transmitter.
5 - Horn
Output
Timing:
Control the minimum horn
pulse
time
in
milli seconds,
some vehicles will
require a longer pulse to activate the factory horn.
16mS
1
OmS
30mS 40mS 50mS
6 -
Real Panic:
Controls
the panic out when triggered from the transmitter.
ON
- Randomized horn honks when panic is triggered.
OFF-
Standard pattern horn honks when panic
is
triggered.
7 -
AUX
1:
Controls
the VIOLET/BLACK
AUX 1 output activation type and timing.
1 Second
Pulse -
Single 1 second pulse.
Latched-
Output stays active until button is pressed again.
Latched
untiiiGN
ON-
Output
stays active
until
the
ignition is turned on.
Dome Light
Output
-
Output
is used for
illuminated
entry and is not controlled
by the AUX
1 function
of
the transmitter.
8-
AUX
2:
Controls
the
WHITE/BLACK
AUX 2 output activation type and timing.
1
Second
Pulse -
Single 1 second pulse.
Latched -
Output stays active until button is pressed again.
Latched
until IGN ON
-
Output stays active until
the
ignition is turned on.
1
0 Second
Pulse with Arm -
Output
stays active
for
1
0
seconds with press
of
lock
button.
1
0 Second
Pulse with Disarm -
Output
stays active for 1
0
seconds with
press
of
unlock button.
2014 Voxx Electronics Corporation. All rights reserved.