Owner's Manual
Table Of Contents
- Owner's Guide
- Installation and Reference Guide
- Table of Contents
- Before You Begin
- Wire Connection Guide
- Additional Ports
- Set Up & Programming
- Transmitter Programming - Feature Bank 1
- Manual Feature Programming - Feature Bank 2 & 3
- Manual Feature Programming - Feature Bank 4 & 5 - N/A
- Shock Sensor Programming, Adjustment and Testing - Feature Bank 6
- Code Alarm Utility App Feature Programming / Firmware Updates (optional)
- Dome Light Delay / Theater Dimming
- Chirp Delete - User Accessible
- User Selectable LED
- Feature Descriptions
- Transmitter Button Functions
- Security Trigger Zones
21
2019 Voxx Electronics Corporation. All rights reserved.
Feature Bank 2 - Security
1 - Silent Choice: Controls the normal arm/disarm chirps of the security system.
ON - Silentarming/disarminguponrstpressoflock/unlock,pressinglock/
unlock a second time will activate the arm/disarm chirps respectively. The
system will only sound the arm/disarm chirps upon a second press of the
lock/unlock buttons.
OFF - normalarm/disarmchirpsupontherstpressoflock/unlock.
2 - Door Locks: Determines manual or automatic locking of the vehicle’s doors.
Active - Requires use of the transmitter to lock the vehicle’s doors.
Passive - Automatically locks the vehicle’s doors 1 minute after the last door
is closed.
Note: For Passive Locks, feature #3, System Arming, must also be
set to passive.
3 - System Arming: Determines manual or automatic locking of the vehicle’s doors.
Active - Requires use of the transmitter to arm the security system.
Passive - Automatically arms the security system 1 minute after the last
door is closed
4 - System Notications: This feature selects which output(s) will sound the
system’sarm/disarmchirps.Thisfeaturedoesnoteectthetriggeredstateofthe
security system and during a triggered cycle, both the siren and horn outputs will
activate respectively.
Siren & Horn – Siren and horn both sound when arming/disarming the system.
Siren Only – Only the siren will sound when arming/disarming the system.
Horn Only - Only the horn will sound when arming/disarming the system.
5 - Alarm Duration: Determines the length of time the system will sound the siren/
horn during a full trigger event.
30 Seconds – When triggered, the system will sound the siren/horn for 30
seconds then stop. The unit will remain armed and may be triggered again.
60 Seconds – When triggered, the system will sound the siren/horn for 60
seconds then stop. The unit will remain armed and may be triggered again.
Feature Descriptions