Adjusting the Shock Sensor
1.
Increase sensitivity by turning the adjustment dial clockwise.
2.
Decrease sensitivity by turning the adjustment dial counter clockwise.
Testing the Shock Sensor
Arm the system and
wait
6 seconds for the zone to stabilize, then firmly strike
the vehicles bumper.
Chirp Delete - User Accessible
System ARM/DISARM chirps can be toggled ON
or
OFF
without entering the
programming feature banks.
1.
Turn the ignition ON then OFF.
2. Press and release the valet/programming button 3 times. The system
will respond with 1 chirp for ON or 2 chirps for OFF.
Dome Light Delay I Theater Dimming
The system can be programed to delay arming after the lock button is pressed (60
second max) for vehicles with a
dome
light delay
or
theater dimming feature. Once
programed the system will 'learn' the timing of the
dome
light
delay
and add 2
seconds before arming.
1.
Close all doors with ignition off.
2. Using the transmitter press LOCK, UNLOCK,
LOCK
,UNLOCK,
LOCK,
UNLOCK, LOCK.
The
LED will light solid to indicate the system has
entered DOME DELAY LEARN MODE.
3.
Immediately OPEN then CLOSE the door
WITHOUT
disarming the
system.
The
system will then monitor the
door
trigger wire. Once the
dome
light turns off, the system will then add 2 seconds and then exit
the learning mode.
4.
The
LED will begin to flash indicating the system has exited the
learning
mode
and is now armed.
2010 Audiovox Electronics Corporation. All rights reserved.