Owner's Manual

Feature Bank 3 - Output Control
1 - Extended Lock Pulse: Controls the timing of the BLUE and GREEN lock
output wires.
1 Second - Single 1 second lock pulse, single 1 second unlock pulse.
3.5 Seconds - Single 3.5 second lock pulse, single 3.5 second unlock pulse.
1 Second Lock, Double Pulse Unlock - Single 1 second lock pulse, double 1
second unlock pulse.
30 Second Lock, Double Pulse Unlock - Single 30 second lock pulse, double
1 second unlock pulse.
Double Pulse Lock, 1 Second Unlock - Double 1 second lock pulse, single 1
second unlock pulse.
2 -
Factory Disarm: Controls the timing of the L
T.
GREEN/BLACK factory disarm
output.
Factory Disarm - Single 1 second pulse with unlock and remote start
activation.
2nd Unlock - Same output as unlock with 2nd press of unlock only.
3 -
Ignition Controlled Locks: Control of door locks when the ignition is cycled
ON or
OFF.
OFF - Door locks not activated by ignition.
Lock and Unlock - Doors lock when ignition
is
turned
on
and unlock when
ignition
is
turned off.
Lock Only - Doors lock when ignition
is
turned on.
Unlock Only - Doors unlock when ignition
is
turned off.
4 -
Trunk Output Timing: Control of the REDIWHITE trunk release output wire
when trunk release
is
activated from the transmitter.
Push and Hold - Output
is
continuously active until transmitter button is
released.
10 Seconds - Output stays active for 10 seconds regardless of length
button press
on
transmitter.
20 Seconds - Output stays active for 20 seconds regardless of length
button press
on
transmitter.
Latched until
IGN
ON
- Output stays active until the ignition is turned on.
Latched
ON
until Button Press - Output stays active until deacvtivated by
transmitter.