Programming instructions
18
F. Programming Options
Default settings in
BOLD
OPTION DESCRIPTION
Option Bank 0 - 3 Chirps (Learn Transmitters)
Option Bank One - 4 Chirps (Alarm Options)
STATUS INDICATOR
1. Lite Touch Adj. ARM raises sensitivity: DISARM lowers sensitivity
2. Full Shock Adj ARM raises sensitivity: DISARM lowers sensitivity
3. Passive Starter Kill Engages starter kill after one minute O N
OFF
4. Passive Arming Alarm automatically arms 60 sec. O N
OFF
after ignition is turned off
5. Passive Locks Automatic ly Locks Doors After 60 Sec. O N
OFF
6. Confirmation Chirps (1) Yes (2) No confirmation chirps
ON
(1) OFF(2)
7. Extended Horn Pulse Extends the horn output time O N
OFF
Option Bank Two - 5 Chirps (Convenience Options)
1. illuminated Exit Dome goes active when ignition key is turned off
ON
OFF
2. Personalized Transmitters Refer to pg ?? for reference O N
OFF
3. Real Panic Horn Output (1) Random pulsed (2) Steady pulsed output
ON
(1) OFF(2
4. Trunk Output timing (1) 20 seconds latched (2) Push and ho ld ON(1)
OFF(2)
5. Noise Control Alarm will (1) sound for five 30-sec. cycles,
ON
(1) OFF(2)
then ignore trigger or (2) Sound continuously when triggered
6. Turbo Timer Enables Turbo Timer Option O N
OFF
Option Bank Three - 6 Chirps (Keyless Options)
1. Ford “Slam Lock” Option Delays door lock time for Ford unlock disable O N
OFF
2. Double Pulse Unlock Unit Provides 2 pulses when unlocked O N
OFF
3. Ignition Triggered Lock Doors lock when all doors are closed and
ON
OFF
ignition is turned on
4. Ignition Triggered Unlock Doors l ock when all doors are closed and
ON
OFF
ignition is turned off
5. Delayed Door Lock 3 sec. delay locking for theater dimming O N
OFF
6. Extended Locks Lock duration is (1) 5 sec. or (2) .6 sec. ON(1)
OFF
(2)
4. System Power-Up and Programming, cont’d
Option Bank Four - 7 Chirps (Car Start Options)
1. Tach Mode (1) Use blind crank (2) Use Tach input O N
OFF
2. Blind Crank (1) Crank average (2) Adjustable
ON
OFF
3. Adjustable Crank Time Refer to Table 1.2 on pg. 20, LOCK advances to next time
4. Diesel Mode 15 Sec Delay before Crank O N
OFF
5. Run Time (1) 25 Minutes (2) 12 Minutes ON (1)
OFF
(2)
6. Lock After Start Relocks the doors after Remote Start
ON
OFF
7. 1 Button Start (1) 1 button Remote Start
ON(1)
OFF(2)
(2) 2 Button Remote Start
8. Ignore Dome After Start Door Trigger Ignored for 1 min. After Start O N
OFF
CA-640.p65 10/20/03, 7:48 PM18