Programming instructions

16
Note: Transmitters must be programmed prior to these steps.
1. Repeat steps 1-4 of Remote Transmitter Programming
(previous page).
2. Press and release the emergency override button.
The horn or siren will sound four (4) times. This indicates that the
unit has entered the Alarm Options (Option Bank 1).
3. Press the FIND/PANIC button to advance to the next feature.
The siren or horn will sound a number of times to indicate the
number of the option.
4. Press the LOCK button to turn the option on or off. The vehicle
status indicator on the dashboard indicates whether an option
is on or off.
• If the selected option is ON, the indicator will light.
• If the selected option is OFF, the indicator will turn off.
• The status indicator will turn on or off when an option is changed.
5. When changes are complete, press and release the emergency
override button to continue to the next option bank. (Siren or horn
will sound five (5) times.)
6. To reset all options back to factory defaults, press the UNLOCK
button.
Note: Installer Option bank will never reset.
7. Turn ignition off to exit programming.
See Options Chart on pages 19 - 20.
4. System Power-Up and Programming, cont’d
FIND/PANIC
Press to
Advance to Next
Setting
LOCK
Press to Turn
Selected
Feature
On /Off
UNLOCK
Press to Restore
All Settings to
Factory Defaults
C. Programming Selectable Options
CA-640.p65 10/20/03, 7:48 PM16