User`s manual
Table Of Contents
- 535 User's Manual
- Table of Contents
- Chapter 1: Introduction
- Chapter 2: Basic Interface
- Chapter 3: Installation
- Chapter 4: Hardware Set Up
- Chapter 5: Software Configuration
- Chapter 6: Tuning
- Chapter 7: Applications
- Control Type
- Alarms
- Duplex Control
- Slidewire Position Proportioning Control
- Velocity Position Proportioning Control
- Staged Outputs
- Retransmission
- Digital Inputs
- Remote Setpoint
- Multiple Setpoints
- Multiple Sets of PID Values
- POWERBACK
- Self Tune–POWERTUNE®
- Ramp-To-Setpoint
- Input Linearization
- Load Line
- Security
- Reset Inhibition
- Process Variable Reading Correction
- Serial Communications
- Cascade Control
- Ratio Control
- Appendix 1: Menu Flowcharts
- Appendix 2: Parts List
- Appendix 3: Troubleshooting
- Appendix 4: Calibration
- Appendix 5: Specifications
- Appendix 6: Glossary
- Appendix 7: Isolation Block Diagram
- Return Procedures and Warranty Information
- 500 Series Process Controllers User's Manual

Tuning
68 Chapter 6 535 User's Manual
TUNING
Parameter Definition Values
1. ADAPTIVE Activates the self tune algorithm.
2. PRETUNE Activates the pretune algorithm.
3. POWR. BACK Reduces setpoint overshoot.
4. PROP. BND.:1 Defines the proportional band for PID set 1.
5. RESET:1 Defines the integral time for PID set 1.
6. RATE:1 Defines the derivative time for PID set 1.
7. MAN. RST.:1 Defines the manual reset for PID set 1.
8. CYCLE TM.:1 Defines the cycle time for control output 1.
9. DEADBAND:1 Defines the dead band for control output 1.
10. P. PROP. D.B. Defines the dead band setting for a slidewire output.
11A. PID OFST.:1 For duplex applications, defines the offset for the first output.
11B. ON OFST.:1 For On/Off applications, defines the offset for the first output.
12A. PID OFST.:2 For duplex applications, defines the offset for the 2nd output.
12B. ON OFST.:2 For On/Off applications, defines the offset for the 2nd output.
13. REL. GAIN:2 Defines the adjustment factor for the output 2 prop. band.
14. CYCLE TM.:2 Defines the cycle time for control output 2.
15. DEADBAND:2 Defines the dead band for control output 2.
16. RSP RATIO Defines the multiplier applied to the remote set point.
17. RSP BIAS Defines the bias (additive term) applied to the remote set point.
18. NO. OF PID Defines the number of stored and available PID sets.
19. PID TRIP Defines the variable used to select the various PID sets.
20. TRIP:1 Defines the value that triggers a change to primary PID set.
21. PROP. BND.:2 Defines the proportional band for PID set 2.
22. RESET:2 Defines the integral time for PID set 2.
23. RATE:2 Defines the derivative time for PID set 2.
24. MAN. RST.:2 Defines the manual reset (or load line) for PID set 2.
25. TRIP:2 Defines the value that triggers a change to the 2nd PID set.
26. PROP. BND.:3 Defines the proportional band for PID set 3.
27. RESET:3 Defines the integral time for PID set 3.
28. RATE:3 Defines the derivative time for PID set 3.
29. MAN. RST.:3 Defines the manual reset (or load line) for PID set 3.