Technical data

Number Meaning Min Max Default Unit
36
Intake air fan Level 3
17 100 90 %
37
Current level of exhaust air fan
current
value
%
38
Current level of intake air fan
current
value
%
P4 Temperatures
Number Meaning Min Max Default Unit
41
Comfort temperature
15 28 18
°C
42 Post-heater enable temperature 5 40 18
°C
43 GHE starting temperature low 0 15 7
°C
44 GHE starting temperature high 10 35 23
°C
45
Current value of T1 (outside air)
current
value
°C
46
Current value of T3 (exhaust air)
current
value
°C
47
Current value of T4 (discharged air)
current
value
°C
P5 Status – depends on type
Number Meaning
0 1
Default
51
No function
- - 0
52 No function - - 0
53 No function - - 0
54 Bypass installed No Yes Yes
55 No function - - 0
With the COMFOAIR 140, parameters P51, P52, P53 and P55 must
always be set to “0” and P54 always set to “1”.
P6 Malfunction register
Number Meaning
Display
61
Last malfunction Code, see 8.1 “Alarm and malfunction displays”
62
Last malfunction
but one
Code, see 8.1 “Alarm and malfunction displays”
63
Last malfunction
but two
Code, see 8.1 “Alarm and malfunction displays”