Use the <RIGHT> arrow key to select the mode of
operation required.
Press the <LEFT> arrow key again to control
Ventilation options.
Use the <RIGHT> arrow key to select the mode of
Ventilation required. Normally set to Automatic.
Press the <LEFT> arrow key again to control Fan
options.
Use the <RIGHT> arrow key to select the mode of
Fan operation required. Normally set to
Automatic.
Press the <END> key to exit to the normal
display.
On Turn the Airconditioning On.
Off Turn the Airconditioning Off.
TimeZone Airconditioning system will be automatically turned On and Off
by the TimeZone assigned to it by the installer.
Recirculate Forces the system to use Recirculated air.
Fresh Air Forces the system to use Fresh air.
Automatic Airconditioning system will automatically select Recirculated or
Fresh air based on whether Heating or Cooling is required and
the status of the Fresh Air thermostat.
AC001 Fan ->AC001 Fan ->
AC001 Fan ->AC001 Fan ->
AC001 Fan ->
AutomaticAutomatic
AutomaticAutomatic
Automatic
Always On Fan is always on to circulate air regardless of Compressor on/off.
Heat Pump Allows warmer air from the “Return air zone” to be pumped to
other zones without using the compressor for heating. Used when
the return air zone provides another source of heat such as a wood
heater.
Automatic Compressor on/off will automatically control Fan on/off.