15. ALARM GROUP RESTRICTIONS
Alarm group restrictions provide means to define certain alarm control functions for
certain areas in alarm groups. Alarm control can be restricted to “Timed disarm” and
“Arm/Reset only”.
Two special restrictions are available:
Alarm group restriction Emergency
Alarm group restriction Counter
The combination of alarm group and alarm group restriction provides the available alarm
control to a user (or keyswitch). An alarm group is only restricted if a restriction is
programmed. The restriction is only applicable if the areas from the alarm group
restriction are also in the alarm group. Areas that are not in the alarm group restriction but
are available in the alarm group, do not have any restriction (except if programmed in the
Alarm groups).
Examples:
1. Cleaners are only allowed to arm/reset area 1, 2 and 3. They are not allowed to
disarm. Area 4 however, they can arm and disarm without restrictions.
An alarm group is programmed with areas 1 through 4 and alarm group restriction 1.
Alarm group restriction 1 has arm/reset only for areas 1, 2 and 3.
2. A security guard has permission to disarm areas 3, 4 and 5. After 15 minutes, the
areas should re-arm automatically.
An alarm group is programmed with areas 3, 4 and 5 and alarm group restriction 3.
Alarm group restriction 3 has areas 3, 4 and 5 for timed disarm. In Timers, the
disarmed time is programmed for 15 minutes.
Alarm group restriction options
1. Timed disarm of areas
The Timed Disarm option applies to areas assigned to an alarm group and programmed
as Timed disarm areas in the Alarm group restriction menu.
Alarm group restrictions 1 to 6:
When disarming the programmed
areas and a timer starts running.
The areas arm again when the timer has
expired unless other timers are still running.
Users can arm the area by re-entering their
code, provided the display does not show
Ending. If other timers are running and the
code is re-entered, the individual alarm
group restriction is cleared but the area is
not armed.
Users can extend the timer by re-entering
their code when the display shows Ending
for their alarm group restriction.
A buzzer sounds as a warning when the
timer is running out and the area is about to
arm.