System information
ATS 2000/3000/4000/4500 Programming manual 97
99-
A
ll, 98-STD, 97-Output/Groups, 95 Software IUM
Option:
14. RESET TO DEFAULT
Sometimes it is necessary to bring the control panel back to factory defaults. For example
when a system is going to be programmed for the first time or when programming a
system that has been de-powered for an extended period (more then 2 weeks).
14.1. Select default option
Select the programmed options to bring back to factory default.
99-All
Resets all the system records to the factory default. All
programming is erased.
98-STD (standard)
Resets some of the programming menus. The following
menus are defaulted:
Area database
Alarm groups (11-29)
Timers
System options
Auto reset
Timezones
Alarm group restrictions
Auto Arm/disarm
Areas assigned to vaults
Area linking
- Timezone to follow output
97-Outputs and groups
Resets the event to output records, the door and floor
groups.
95-Software IUM
This new option upgraded the panel to Software IUM. By
using this option the different memories will be converted
as follows:
Standard: No memory 1MB
Number of standard users 50 11000
Number of IUM users 0 0
Soft IUM:
Number of standard users 50 11000
Number of IUM users 50 2232
Users’ Against Memory Size and Type (There are two types of memory configurations:
Standard Memory and Intelligent User Memory configuration. Refer to table below)
No. of cards
No. of PIN
codes
No. of users
No memory / Soft IUM 50 50 50
1Mb Standard Memory 11000 1000 11000
1Mb Soft IUM 2000 2000 2000
4Mb IUM 17,872 17,872 17,872
8Mb IUM 65,532 65,532 65,532