System information
ATS 2000/3000/4000/4500 Programming manual 83
NO
–
Enable Line Monito
r
*-Change 0 - Skip
NO
–
Monitor Service Tones
*-Change 0 - Skip
Y
ES
–
3 Digit SIA Extensions
*-Change 0 - Skip
NO
–
ISDN Point to Point
*-Change 0 - Skip
NO
–
Enable ISDN Line Fault Monito
r
*-Change 0 - Skip
NO
–
200 Baud Reverse Area Open/Close
*-Change 0 - Skip
9.5. Enable PSTN line fault monitor
A line monitor will detect if the line voltage on the telephone network is within limits. If not,
a telephone line failure will occur.
YES Enable the line monitor.
NO Line monitor is disabled.
Press 0 to skip further options and move to central stations.
9.6. Monitor service tones
Reserved for future use
9.7. Use 3 digit SIA extensions
Select if SIA reporting uses 2 or 3 digit zone, point or user numbers. When 2 digits are
used, numbers above 99 will be converted to 99.
YES SIA reporting uses 3 digit numbers.
NO SIA reporting uses 2 digit numbers.
Press 0 to skip further options and move to central stations.
9.8. ISDN point to point (Yes/No)
This option allows you to select the point to point mode of operation for the plug-in ISDN
dialler.
9.9. Enable ISDN line fault monitor
(Yes/No)
If set to Yes, the line monitor will detect if the line condition on the telephone network is
within limits. If it is not, a telephone line fault condition will be activated.
9.10. 200 Baud Reverse Area
armed/disarmed (open/close)
If set to NO, disarm events are reported as type ‘A’ and arm events are reported as type
‘R’ (Default)
If set to YES, disarm events are reported as type ‘R’ and arm events are reported as type
‘A’