System information

ATS 2000/3000/4000/4500 Programming manual 75
NO
Inhibit zone includes tampe
r
*-Change 0 - Skip
NO
Report Multiple Alarms In Zone
*-Change 0 - Skip
NO
Report Each Restord Multiple Alarm
*-Change 0 - Skip
NO
Engineer Reset for System Alarms
*-Change 0 - Skip
7.29. Inhibit zone includes tamper
Zone tampers in default programming will be inhibited when a zone is inhibited.
YES When a zone is inhibited, also the tamper is inhibited. No tamper alarm will
occur anymore.
NO An inhibited zone will only have inhibited alarms. Tamper alarms will still occur.
Press 0 to skip further options and leave system options.
7.30. Report multiple alarms
The system is able to report multiple alarms that occured in a zone (depending on the
reporting format).
YES Report multiple alarms as a seperate alarm for each alarm that occurs.
NO Only report the first alarm. Every next alarm that occurs will not be reported.
Press 0 to skip further options and leave system options.
7.31. Report multiple restores
The system is able to generate a restore for each alarm being reported, even for multiple
alarms in a zone.
YES Report a restore for every alarm that occured.
NO Report only one restore for every zone that generated an alarm.
Press 0 to skip further options and leave system options.
7.32. Engineer reset on system alarms
If an engineer reset is required on system alarms, set this option to YES. A user can not
arm any area until an engineer reset has been performed.
YES After a system alarm, an engineer reset is required.
NO No engineer reset required.
Press 0 to skip further options and leave system options.
How to perform an engineer reset
Whenever an engineer reset is required, the panel will display a 4-digit code. This
code is a reference to a special code that can be found in the TITAN software
package (menu control) or contact your local Aritech distributor.