NO
–
Two Users before Programming Code
*-Change 0 - Skip
NO
–
Display Alarm Instant On LCD
*-Change 0 - Skip
NO
–
Sirens Only After Report Fail (FTC)
*-Change 0 - Skip
NO
–
Financial Options
*-Change 0 - Skip
7.22. Two users before programming
code
Determines that two users are required to enter their PIN code to enable programming of
users (user menu 14). When entering this option, a request for a second PIN code is
shown before access is granted.
User 50 (Master code) is not required to have a second code to authorise the option.
YES Two users are required to enter their PIN code before access is granted to
program users.
NO No validation is needed when entering user menu 14, Program users.
Press 0 to skip further options and leave system options.
See the Manager’s guide for more information on programming users.
7.23. Display alarms instantly on LCD
Indicate if alarms should be displayed immediately on LCD.
YES Details of the first alarm are displayed instantly on the LCD arming station.
Details of other alarms can be viewed on the LCD arming station by pressing
the [ENTER] key twice.
NO Details of all alarms can be viewed on the LCD arming station by pressing the
[ENTER] key twice.
Press 0 to skip further options and leave system options.
7.24. Sirens only after fail to report
When set to YES, Siren event flags are only activated on alarms if the ATS control panel
has failed to report to the central station. Fail To Report (FTC) is registered at the end of
the fourth dial attempt. The siren activates for the normal siren cut-off time programmed.
YES Sirens will only activate on alarms when a FTC has occurred.
NO Sirens will operate on alarms.
Press 0 to skip further options and leave system options.
See also Siren cut-off time in Timers (page 64) and Event Flags (page 133)
7.25. Financial institution options
Activates three special options (generally applicable to financial institution installations).
1. Film counters are enabled during the Disarm test mode.
2. Alarm group restriction 2 or Alarm group restriction 6 disable delayed Disarmed Alarm
zones.