System information

ATS2000/3000/4000/4500 Programming manual
72
NO
Disable Insert Of Alm/Grp Restr.
*-Change 0 - Skip
NO
Disable Area LEDs That Dont Report
*-Change 0 - Skip
NO
Disable Code From Displaying
*-Change 0 - Skip
NO
Disable Flashing Area LEDs
*-Change 0 - Skip
YES 0 [ENTER] can not be used to stop cameras operating. The cameras continue
to operate until someone who is authorised to control cameras, resets them.
NO 0 [ENTER] stops the cameras operating (after pressing [ENTER] [ENTER] for
the "Quick alarm log".
Press 0 to skip further options and leave system options.
See also the manager guide regarding alarms, camera’s and alarm logs.
7.18. Disable auto insert of alarm
group restriction
Disables the option to treat areas as vaults. By disabling this option, the non-vault areas
will not be automatically armed.
YES Disables the special procedure for automatically timing on non-vault areas
when arming vaults.
NO Enables the special procedure for automatically timing on non-vault areas
when arming vaults, provided all the applicable values are programmed.
Press 0 to skip further options and leave system options.
See Areas assigned to vaults on page
108.
7.19. Reserved
7.20. Disable code from displaying
Disable display of the PIN code when programming users
YES PIN codes are not visible (except for master installer). The display shows “PIN
codes can not be viewed”.
NO PIN codes are visible to.
Press 0 to skip further options and leave system options.
See also the manager guide regarding programming codes.
7.21. Disable flashing area LED’s
Indicate if area LED’s should flash when there is an alarm and/or tamper alarm in the
area.
YES The area LED will not flash on alarm.
NO The area LED will flash on alarm.
Press 0 to skip further options and leave system options.