System information
ATS 2000/3000/4000/4500 Programming manual 69
No Alarm Code Prefix
No Digits:
LCD Rotation Delay Is 0
Time:
Rotate Speed Is 0
Time:
NO
–
Dual zone
*-Change 0 - Skip
The zone event text only appears when the zones are active, for example “Freezer open”.
See also Zone database on page 17 and Program text on page 89.
7.7. Alarm code prefix
The alarm code prefix enables user codes to be used for both access control and alarm
control. The prefix indicated the number of digits that have to be entered to have alarm
control. If those digits are not entered, only access control can be performed.
For example:
If the alarm code prefix is two digits and a users PIN code is 123456, then you would
enter 123456 for alarm control or 3456 for access control. A value between one to four
digits can be entered.
The minimum PIN code length entered has to be 4 digits. The total length of a
users PIN code is 4 + alarm code prefix.
7.8. LCD text rotation delay
The time before text on the LCD display starts rotating can be altered. The default value
0, which is equal to 8.
Any value from 9 – 15 increases the time before text rotation starts.
Any value from 1 – 7 decreases the time before text rotation starts.
This option can only be programmed for LCD arming stations, like ATS1100.
7.9. LCD text rotation speed
Not only the time before text rotation starts can be altered, but also the speed with which
the text rotates. The faster the speed, the harder to read. But when the speed is too slow,
long texts might take too long to show. The default value 0, which is equal to 8.
Any value from 9 – 15 decreases the text rotation speed.
Any value from 1 – 7 increases the text rotation speed.
This option can only be programmed for LCD arming stations, like the ATS1100.
7.10. Dual zone enabled
Determines if dual zone is used. For dual zone to operate, every zone needs two
resistors of 4,7 kΩ. This enables the panel to detect whether a zone is in normal state, is
active or is tampered.