System information
ATS2000/3000/4000/4500 Programming manual
68
1, Enable Auto Test
Option:
Number Of Output Controllers: 2
How Many:
Zone Text: 0103, Gate
Text No:
Relates to zone types 23-26 and 36-39 (camera count). See Zone database on
page 17.
7.4. Test mode
The test mode determines if or when an arm or disarm tests has to be performed
(formerly called walktest).
There are four options available. An option is programmed using its reference number.
Option Function
0 No Test No automatic tests. A disarm test can be performed using
User menu 13, Start auto disarm test.
1 Enable Auto Test The disarm or arm test starts automatically when the system
is disarmed or armed.
2 Manual Disarm
Test/Auto Arm Test
The arm test starts automatically when the system is armed.
The disarm test can only be done using User menu 13, Start
auto disarm test.
3 Auto Disarm Test
Only
The disarm test starts automatically when the system is
disarmed. No arm test is available.
For the "Auto disarm test" to operate, the area(s) containing the zones to test have
to be programmed as vaults. See Areas assigned to vaults (page 108).
This record does not affect manual testing of any individual zone (User menu 12).
See the Manager’s guide.
7.5. No. of output controllers
Enter the number of output controllers that are fitted to the main control panel (J14, see
installation guide). An output controller has 8 outputs available.
Valid values:
0 No output controller or a 4-way relay (ATS1810).
1 – 32 Indicates the number of output controllers (ATS1811). The 16-way open
collector card (ATS1820) takes up 2 controllers.
Do not enter values here for output controllers fitted to DGP’s.
7.6. Zone event text
When zone types 57 and 58 are active, this zone event text will be displayed on LCD
keypads. The text is taken from the text word library and is programmed as a reference
number. A free programmable text can be programmed using Program text (page 89).