System information

ATS 2000/3000/4000/4500 Programming manual 65
Mains Fail Delay Time (Min). 10
Time:
Delay Report Alarms for (Sec). 0
Time:
A
to B Alarm Delay (ACPO) for (Sec). 0
Time:
Screensaver Timeout (Sec). 0
Time:
RAS Card & PIN Timeout (Sec).
Time:
Double Knock Interval (Min).
Time:
6.22. Mains fail delay time
The delay time (0 – 255 minutes) before a Mains Fail is reported to the central station.
Enter a value of “0” for no delay.
See also Program system event flags (page 130) and Communication options
(page 82).
6.23. Delay reporting alarms for
The delay time (0 - 255 seconds) before a burglar alarm (BA) or BA Class Tamper Alarm
(TA) is reported to the central station. Can be used to prevent alarm reporting for users
that have problems disarming their area in time. After a burglar alarm or input tamper
activation, there will be a delay of 20 seconds before the burglar alarm (BA) or BA Class
Tamper Alarm (TA) will be reported to the Central Station. All other (non-BA & non-TA)
Alarms are reported immediately, without delay.
6.24. A to B alarm delay (ACPO)
The delay time (0 – 255 seconds) that the system waits for a second alarm. If the second
alarm happens within the delay time, it will be reported as a verified alarm.
See also A&B alarm reporting (ACPO only) in Area database (page 36).
6.25. Screensaver timeout time
(Scandinavian indicator)
The screensaver timeout value will be in the range of 5 - 180 seconds with an accuracy of
1 second. The screensaver timer will be reset with the programmed period every time a
RAS key is pressed when the screensaver is not active. The system user can also
activate the screensaver manually by pressing the CLEAR key at the Enter Code prompt
6.26. RAS CARD & PIN Timeout (Sec).
Allows you to set the delay time (0-255 seconds) between badging the card and entering
the PIN code. (default is 8 seconds)
6.27. Double Knock Interval (Min).
If enabled for a particular zone, Double Knock Interval specifies the maximum permitted
time a zone may remain active. If the time for which a zone remains active exceeds the