System information

ATS 2000/3000/4000/4500 Programming manual 55
NO
Restricted To Arm & Reset
*-Change 0 - Skip:
NO
Restricted To Disarm Only
*-Change 0 - Skip:
NO
Restricted To Reset Only
*-Change 0 - Skip:
NO
Auto Inhibit Active Zones
*-Change 0 - Skip:
YES Disarming the area will not automatically uninhibit zones in the area. Used for
cleaners, etc.
NO Disarming the area will automatically uninhibit zones.
Press 0 to go to the user menu items available.
Automatic uninhibit in System options (page 67) has to be set to YES.
5.1.9. Arm and reset only
Restricts alarm control to arm and alarm reset only.
YES Only arm and reset are allowed.
NO There are no alarm control restrictions.
Press 0 to go to the user menu items available..
Alarm system control has to be set to YES
5.1.10. Disarm only
Restricts alarm control to disarm only.
YES Only disarm is allowed.
NO There are no alarm system control restrictions.
Press 0 to go to the user menu items available.
Alarm system control has to be set to YES.
5.1.11. Alarm reset only
Restricts alarm control to alarm reset only.
YES Only reset alarm is allowed.
NO There are no alarm system control restrictions.
Press 0 to go to the user menu items available.
Alarm system control has to be set to YES
5.1.12. Auto inhibit active zones
Determines if active zones on arming have to be automatically inhibited.