System information
ATS 2000/3000/4000/4500 Programming manual 53
A
lm/Grp Name: 0297, Engineering
Text No:
1,2,3,5,7,8,9,
Area:
NO-Can this GRP Be Assigned To Users
*-Change 0 - Skip:
Y
ES
–
Alarm System Control
*-Change 0 - Skip:
5.1.1. Alarm group name
Every alarm group can be programmed with a name to identify the alarm group.
The words are selected from a list already held by the ATS system. They can be either
from the list of standard words available (see the library on page 90), or from a list of
words that you have programmed yourself (see Program text on page 89).
The display shows the current alarm group name, preceded by its reference number).
5.1.2. Areas assigned
Assign the areas to be controlled by the alarm group. An alarm group can only control the
functions of areas that are assigned to it.
5.1.3. User alarm group
Define if the alarm group can be assigned to users, or only to zones and RAS’s.
YES This alarm group can be assigned to users. The group is displayed in the list of
alarm groups when creating a user in User menu 14 - User codes. This option
is not set for alternate user alarm groups.
NO This alarm group is for a zone, door or RAS.
Press 0 to go to the user menu items available.
An alarm group is only displayed in User Codes when the user who is creating a
new user has at least the same options (includes check of alternate alarm group).
A user cannot create a code for another user who has higher security clearance.
5.1.4. Alarm system control
This record lets you assign alarm system control functions to a user, door or RAS. Only
when alarm system control is enabled can users arm or disarm areas in the alarm group.
YES Alarm system control is enabled. Users, doors or RAS’s can arm or disarm the
areas in the alarm group.
NO No alarm system control available. Access control functions and any user
menu options specified are still valid.
Press 0 to go to the user menu items available.
You must set this record to YES if any of the alarm group restrictions in the Alarm
Group are set to YES.