System information
ATS2000/3000/4000/4500 Programming manual
52
A
larm Group **WARNING**
Alm-Grp:
5.1. Alarm group number
Every alarm group must be numbered. They are numbered from 1 to 138.
Alarm groups 1-10 are hard coded into the system. They can be viewed but can not be
changed as they contain master control settings and default settings.
Table 5: Default settings for alarm groups
Number Name User menu options
1 No access All set to NO
2 Master RAS or door All set to YES
3 Master code access All set to YES
4 8 area master RAS (1-8) All set to YES
5 8 area master RAS (9-16) All set to YES
6 Master user All set to YES except 19
7 Manager All set to YES except 19
8 Master Engineer All set to YES except 8-11, 14, 16-18
9 Master Service All set to YES except 8-11, 14, 16-18
and timezone 25.
10 Spare alarm group All set to NO
11 High level master All set to YES except 19
12 Low level master All set to YES except
1,5,9,10,11,14,15,16
13 All area user All set to YES except 1,5,9,10,11
14-29 Area one to area sixteen All set to YES except 1,5,9,10,11
Alarm groups 14 to 29 are for individual areas. The areas assigned to the alarm groups
are as follows:
Alarm group Area Alarm group Area Alarm group Area
14
15
16
17
18
1
2
3
4
5
19
20
21
22
23
6
7
8
9
10
24
25
26
27
28
29
11
12
13
14
15
16
In a new system, alarm groups 11-29 are pre-programmed with some standard
settings. You can change them if necessary. Alarm groups 30-138 are
programmable to suit individual system requirements.