System information

ATS 2000/3000/4000/4500 Programming manual 45
NO
Display Shunting on LCD
* - Change 0 - Skip
Y
ES
ENTER Key Opens Door Only
* - Change 0 - Skip
NO
Door Event Flag On Alarm Codes
* - Change 0 - Skip
Table 4: Using card readers for alarm control:
Programming options
Function
Toggle
Area
Card auto Card
always
Notes
Card OFF - Disarms
Card ON - Arms
NO NO NO ATS1155, ATS1105 ONLY
Card – Disarms
Card – Arms
YES NO YES
3.2.7. ENTER key opens door only
YES When using LCD arming stations, using the [ON] and [OFF] key for alarm
control results in a clearer user interface. It also provides an option to use the
[ENTER] key for opening a door with a keypad.
NO The [ENTER] key unlocks the door, but also provides alarm control and resets
alarms.
See Table 3 on page 44 for further information on options available to arming stations.
Set this option to YES for the best user interface on LCD arming stations.
3.2.8. Door event flag on alarm codes (Alarm codes open door)
YES If user codes with alarm control and door groups perform alarm control, the
door will unlock.
NO User codes with alarm control will not unlock doors.
See Table 3 on page 44 for further information on options available to arming stations.
The user needs to have alarm control and a door group.
3.2.9. Display shunted zone on LCD
YES When a zone is shunted, the text ‘Zone shunted,’ will appear on the display.
NO Nothing is shown when a zone is shunted.
See Table 3 on page 44 for further information on options available to arming stations.