System information

ATS 2000/3000/4000/4500 Programming manual 41
NO
Enable Audio Listen In
* - change, 0 - Skip
NO
Enable Exit Faults
* - change, 0 - Skip
NO
A&B Alarm Reporting (ACPO)
* - change, 0 - Skip
NO
Disable Arming If All Inhibited
* - change, 0 - Skip
KeyBox Time: 5 Mins
Enter Mins:
Tamper No. Event Flag
Event Flag:
2.1.27. Enable audio listen in
When audio listen in has to be enabled for this area on opening, closing or if accessed
after hours, use this option.
YES Audio Listen-in enabled for this area.
NO Adio Listen in disabled.
2.1.28. Enable exit fault reporting
Exit faults occur when an access zone or exit zone is still open at the moment the exit
time expires. On an exit fault a local alarm is generated and a special Exit Fault is
reported to the central station.
YES Enable exit fault reporting.
NO No exit fault reporting.
2.1.29. A&B alarm reporting (ACPO only)
Special facility for ACPO to be able to transmit verfied alarms.
When the first zone activates, an alarm will be transmitted to the central station. If a
second zone activates within the A to B time, a verified alarm will be transmitted.
Otherwise a normal alarm will be transmitted.
YES Use verified A&B reporting.
NO No A&B alarm reporting.
See A to B alarm delay (ACPO) (page 65).
2.1.30. Disable arming if all inputs
inhibited
When arming an area should not be possible if all zones within the area are inhibited, set
this menu to YES.
YES No arming available if all zones in the area are inhibited.
NO Arming is available when all zones in the area are inhibited.
2.1.31. KeyBox timer (min)
Extends the exit time. Immediately after the exit timer expires, the KeyBox timer starts for
a duration of XX minutes. Close the zone before this additional KeyBox timer expires. If it
is not closed, a full alarm will be triggered again even if the previous trigger was also an
alarm. During exit timer + KeyBox timer, openings and closings will not be registered and
will not cause an alarm.
2.1.32. Area Tamper event flag
This event flag becomes active whenever a tamper alarm is detected on an input
associated with the specific area, and is independent of arming state.