System information

ATS 2000/3000/4000/4500 Programming manual 35
Y
es
Engineer Walk Test
* - Change 0 - Skip
No
Double Knock
* - Change 0 - Skip
1.1.33. Engineer Walk Test
YES Zone will be configured to be included in the engineer walk test
NO Zone will not be configured to be included in the engineer walk test
Default will be YES
1.1.34. Double Knock
YES This zone will be configured for double knock activation in a certain time
interval
NO Zone will not be configured for double knock functionality
If set to YES and a zone becomes active, at the point where the alarm condition will
normally be activated, two zone timers shall be triggered. An interval timer is preset with
the value contained in Double Knock Interval, and begins counting downwards. A second
timer (duration) is preset with the value contained in Double Knock Duration, and also
counts downwards.
Note: Only the following zone types are applicable:
Type 1: disarmed alarm
Type 2: armed alarm
Type 4: access alarm
Type 14: access alarm (no arm check)
Default will be No.
.