System information

ATS 2000/3000/4000/4500 Programming manual 25
Zone type Description
42. Entry/Exit Firedoor w
Code
Generates a local alarm when the area is disarmed but does not report
it to the central station.
This alarm can only be acknowledged by entering "USER CODE [OFF]
AREA [ENTER]" on the arming station.
When the area is armed, the exit timer starts and activating the zone
will generate no alarm. If the zone is activated and the exit time has
expired, the entry timer starts. When the exit time has expired, an alarm
will be generated.
Example: A firedoor that is also used to enter the premises.
Note: You need to program the entry/exit timer. See Area database on page
36 for more information.
43. Disarm Zone to Event
Flag
Activates the zone event when the area is disarmed.
Does not perform any action when the area is armed.
Example: Opening a closet activates a buzzer.
44. Firedoor with AlmGrp
Restr.
Generates a local alarm when the area is disarmed but does not report
it to the central station.
This alarm can only be acknowledged by entering "USER CODE [OFF]
AREA [ENTER]" on the arming station
Generates an alarm when the area is armed but the zone can be
disabled when two users with alarm group restrictions have entered
their user code (not necessarily in the same area).
Example: Fire door or emergency door.
Note: You need to program alarm groups (see Alarm groups, page 51) and
alarm group restrictions (see Alarm group restrictions, page 98).
45. (Event Flag/Arm.Alm)
Restr.
Activates the zone event when the area is disarmed.
Generates an alarm when the area is armed, but the zone can be
disabled if two users with alarm group restrictions have entered their
user code (not necessarily in the same area).
Note: You need to program alarm groups (see Alarm groups, page 51) and
alarm group restrictions (see Alarm group restrictions, page 98).
46. Disarm Alm/Arm Gen.
Alm
Generates an alarm if the area is disarmed.
Generates a general burglar alarm if the area is armed.
47. Dis. Alm Susp/Arm
Gen. Alm
When disarmed generates an alarm and activates the cameras. When
the zone closes to normal state, the cameras continue to operate for the
suspicion time.
Generates a general alarm if the area is armed.
48. Camera 1 Film Out Generates an alarm when camera 1 is out of film
49. Camera 2 Film Out Generates an alarm when camera 2 is out of film.
50. Camera 3 Film Out Generates an alarm when camera 3 is out of film.
51. Camera 4 Film Out Generates an alarm when camera 4 is out of film.
52. Camera 5 Film Out Generates an alarm when camera 5 is out of film.
53. Camera 6 Film Out Generates an alarm when camera 6 is out of film.