System information
ATS 2000/3000/4000/4500 Programming manual 23
Zone type Description
31. Latching Keyswitch Used to arm or disarm areas. When the zone switches to:
Active, the areas arm.
Normal state, the areas disarm.
This zone type uses an alarm group to perform the arm/disarm functions.
Example: Latching keyswitch to arm or disarm areas.
Note: You need to program alarm groups (see Alarm groups, page 51).
32. Armed Zone to Event
Flag
• Does not perform any action when the area is disarmed.
• Activates the zone event flag when the area is armed.
Example: Temperature alarm on freezer activates buzzers.
33. 24Hr Alarm & Inhibit This zone type requires different wiring. The zone can have the following
states:
- Shorted generates an alarm
- Normal no alarm
- Active inhibit (no alarms generated)
- Open tamper alarm
Example: Designed for shopping centres where only one zone is available
for each shop. A keyswitch is used to inhibit the zone.
34. Area Dis/AlmGrp
Restr. Arm
A latching keyswitch that has a special function:
• Switching from normal state to active starts the warning time for the
alarm group restriction assigned to the alarm group. When the
warning time expires, the area arms.
• Switching from active to normal state disarms the areas.
Example: A keyswitch in a large building with indication that the area is
going to arm.
Note: You need to program alarm groups (see Alarm groups, page 51),
alarm group restrictions (see Alarm group restrictions, page 98) and a
warning time (see Timers, page 61).
35. Area AlmGrp Restr
Arm Only
A latching keyswitch that has a special function:
• Switching from normal state to active starts the warning time for the
alarm group restriction assigned to the alarm group. When the
warning time expires, the area arms.
• Switching from active to normal state does not perform any action.
Example: a keyswitch in a large building with indication that the area is
going to arm.
Note: You need to program alarm groups (see Alarm groups, page 51),
alarm group restrictions (see Alarm group restrictions, page 98) and a
warning time (see Timers, page 61).
36. Camera 5 Count Used to increment the film counter for camera 5 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used for zones on the ATS control panel.