System information

ATS 2000/3000/4000/4500 Programming manual 23
Zone type Description
31. Latching Keyswitch Used to arm or disarm areas. When the zone switches to:
Active, the areas arm.
Normal state, the areas disarm.
This zone type uses an alarm group to perform the arm/disarm functions.
Example: Latching keyswitch to arm or disarm areas.
Note: You need to program alarm groups (see Alarm groups, page 51).
32. Armed Zone to Event
Flag
Does not perform any action when the area is disarmed.
Activates the zone event flag when the area is armed.
Example: Temperature alarm on freezer activates buzzers.
33. 24Hr Alarm & Inhibit This zone type requires different wiring. The zone can have the following
states:
- Shorted generates an alarm
- Normal no alarm
- Active inhibit (no alarms generated)
- Open tamper alarm
Example: Designed for shopping centres where only one zone is available
for each shop. A keyswitch is used to inhibit the zone.
34. Area Dis/AlmGrp
Restr. Arm
A latching keyswitch that has a special function:
Switching from normal state to active starts the warning time for the
alarm group restriction assigned to the alarm group. When the
warning time expires, the area arms.
Switching from active to normal state disarms the areas.
Example: A keyswitch in a large building with indication that the area is
going to arm.
Note: You need to program alarm groups (see Alarm groups, page 51),
alarm group restrictions (see Alarm group restrictions, page 98) and a
warning time (see Timers, page 61).
35. Area AlmGrp Restr
Arm Only
A latching keyswitch that has a special function:
Switching from normal state to active starts the warning time for the
alarm group restriction assigned to the alarm group. When the
warning time expires, the area arms.
Switching from active to normal state does not perform any action.
Example: a keyswitch in a large building with indication that the area is
going to arm.
Note: You need to program alarm groups (see Alarm groups, page 51),
alarm group restrictions (see Alarm group restrictions, page 98) and a
warning time (see Timers, page 61).
36. Camera 5 Count Used to increment the film counter for camera 5 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used for zones on the ATS control panel.