System information
ATS2000/3000/4000/4500 Programming manual
22
Zone type Description
22. Dis. Delay Reset/Arm
Alm
• Generates an alarm when the area is disarmed but does not report to a
central station until the delayed alarm timer has expired or a second
delayed alarm is activated.
If the zone closes to normal state during the delayed time, it resets
automatically.
• Generates an alarm when the area is armed.
• Example: Hold-up button.
Note: You need to program the delayed alarm time. See Timers on page 61
for more information.
23. Camera 1 Count Used to increment the film counter for camera 1 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used with zones on the ATS control panel.
24. Camera 2 Count Used to increment the film counter for camera 2 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used with zones on the ATS control panel.
25. Camera 3 Count Used to increment the film counter for camera 3 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used with zones on the ATS control panel.
26. Camera 4 Count Used to increment the film counter for camera 4 by connecting a normally
open contact across the zone. The counter increments if the zone switches
from open to short.
Can only be used with zones on the ATS control panel.
27.
Technical with Report When the zone is activated, opened or shorted, it reports to the central
station. A restore is send when the zone de-activates
Example: Temperature alarm on freezer
28. Armed Alarm with
Reset
• Generates no alarm when the area is disarmed.
• Generates an alarm when the area is armed. Resets automatically
when the zone closes to normal state.
Example: Latching glassbreak detector.
29. 24-Hour Alarm with
Reset
• Generates an alarm regardless of the status of the area. Resets
automatically when the zone closes to normal state.
Example: Latching glassbreak detector or smoke detector.
30. Firedoor with Reset
• Generates a local alarm when the area is disarmed but does not report
it to the central station.
This alarm can only be acknowledged by entering "USER CODE [OFF]
AREA [ENTER]" on the arming station. If the zone closes to normal
state, the alarm is reset.
• Generates an alarm when the area is armed.
Example: Firedoor or emergency door.