System information
ATS 2000/3000/4000/4500 Programming manual 165
LCD arming stations - Models ATS1100, ATS1105
Condition Possible cause
• All the LED’s on the arming station are flashing. • The dipswitches may be incorrectly set (the
address set on the arming station may be
incorrect and therefore polling to the arming
station is not being acknowledged).
• The system databus line may be connected
incorrectly.
• The arming station is not being polled (it may not
have been included in arming stations to be
polled when programming arming stations).
• LED’s do not appear to be indicating the correct
condition.
• The arming station type may have been defined
incorrectly:
• LCD arming station must be set to YES.
• The arming station appears to be going off-line
and on-line (indicated by the "RAS Fail"
message on the LCD).
• The termination may be incorrect. See
Installation guide - Cabling.
• An error is indicated when a code is entered on
the keypad (seven beeps).
• An invalid PIN code may have been used.
• The arming station may not have been
programmed with an alarm group.
• The alarm group of the PIN may not permit
access at this arming station.