System information
ATS 2000/3000/4000/4500 Programming manual 149
Test not completed
Press ENTER
Test completed
Press ENTER
Test not completed
Please wait
Note: The warning timer functions as normal during this test. That is, a warning will
sound (if warning time programmed) in the normal fashion.
Otherwise, once all zones have been tested successfully a message ‘Test Complete’ is
displayed, and a message is sent to the central station (see events logged table below).
If the Clear key is pressed while the test is running, ‘Please wait’ display shown below is
displayed while the aux output is pulsed (described further below). When the aux output
pulsing is completed, the walk test will be exited automatically to the install menu.
At the end of the walk test, the walk test event flag will be deactivated.
The test will cause the following events to be logged. These events are sent as messages to
the central monitoring station:
Event logged When logged
ACCESS_TEST_STARTED
When test started
WALK_TEST_ZONE_TESTED
When a zone is tested and Titan is connected to
the panel. (computer connection active event flag
set), Event message includes number of zone
tested.
This event is not sent to central stations.
WALK_TEST_ZONE_NOT_TESTED
When a zone Fails the test and Titan is connected
to the panel. (computer connection active event
flag set) Event message includes number of zone
tested.
This event is not sent to central stations.
ACCESS_TEST_FAILED
If user cancels the test or on test timeout (failed)
ACCESS_TEST_COMPLETED
Test completed successfully
If Titan is connected to the panel, (computer connection active event flag set), the
“WALK_TEST_ZONE_TESTED” , “WALK_TEST_ZONE_NOT_TESTED”,
“ACCESS_TEST_FAILED” or “ACCESS_TEST_COMPLETED” will be logged in
the panel and send to Titan history.
If Titan is NOT connected to the panel (computer connection active event flag NOT
set), the “WALK_TEST_ZONE_TESTED” and
WALK_TEST_ZONE_NOT_TESTED” will be Ignored and not logged.Only the
ACCESS_TEST_FAILED or ACCESS_TEST_COMPLETED will be logged in the
panel.
This is to prevent the panel memory from being filled with events when Titan is not
connected
After each walk test (failed, or completed) a new “Engineer Walk Test Reset” system event
flag will be activated for 5 seconds. Users may use this event flag to switch the aux output
(output 251) to reset any latched detectors in alarm.