System information
ATS 2000/3000/4000/4500 Programming manual 143
BA Burglar Alarm
–
Voice Message 0
Msg. No.
52. VOICE REPORTING
Reporting Code No.
Program the voice messages to be transmitted to the monitoring station, if voice protocol is
programmed. See Communications Options.
Voice Messages can be programmed to report on the following alarm events. More than 1
event may have the same voice message programmed. Range 0-14
Table 1
Reporting
Code No.
Reporting Code Voice Alarm Message
1 Burglar Alarm Default 0 = No msg
2 Tamper Alarm
3 Hold-up Alarm
4 Panic Alarm
5 Fire Alarm
6 Medical Alarm
7 Technical Alarm
8 Mains Fail
9 DGP Offline
10 Area Disarmed
11 Area Armed
As well as the above, the user can also program alarm messages to the following event
codes, allowing for greater flexibility as required. Macros can then be used to trigger these
event codes from various sources.
Eg. An input can be programmed to report to event code 131 BA Perimeter. The input can
then be triggered using macros etc.
Table 2 (User table)
Reporting
Code No.
Reporting Code Voice Alarm Message
12 130 BA Burglary
13 131 BA Perimeter
14 132 BA Interior
15 133 BA 24 Hour
16 134 BA Entry/Exit
17 135 BA Day/Night
18 136 BA Outdoor
19 137 BA Tamper
20 138 BA Near Alarm
21 140 UA General Alarm
22 Low battery
23 Low battery restore
24 Mains restore
25 Technical restore