System information
ATS 2000/3000/4000/4500 Programming manual 133
A
ll Armed No Event Flag
Event Flag:
Line Fault No Event Flag
Event Flag:
Computer Connection No Event Flag
Event Flag:
Battery test active No Event Flag
Event Flag:
Engineer walk test No Event Flag
Event Flag:
Engineer walk test reset No Event Flag
Event Flag:
34.19. All armed pulse event flag
If NFA2P option is YES,an event flag / output shall be provided with or without event
recorder that will be active for 20 seconds, after fully armed condition is true.
34.20. Computer connection active
The flag is active whenever a computer connection between the panel and management
software (Titan) is active. The flag is not to be activated until after the connection has
been established.
34.21. Line fault
This event flag is active whenever a line fault condition is active.
34.22. Battery test active
This event flag determines the endurance of the system backup battery.
34.23. Engineer walk test
This event flag is active whenever an Engineer walk test is active.
34.24. Engineer walk test reset
This event flag is active for 5 seconds after each walk test (failed, or completed).