System information
ATS 2000/3000/4000/4500 Programming manual 125
NO
–
Print Alarm Events
*-Change 0 - Skip
NO
–
Print Access Control Events
*-Change 0 - Skip
NO
–
Print Data Outside Timezone
*-Change 0 - Skip
NO
–
Print During Timezone 0
Tz No:
30.2. Print alarm events
Prints all alarm events.
YES All alarm events are printed.
NO Alarm events are not printed.
Press 0 to leave Printer.
Before anything will be printed real-time, either Print alarm events or Print
access control events has to be set to YES.
30.3. Print access control events
This function prints all access control events.
YES All access control events are printed.
NO Access control events are not printed.
Press 0 to leave Printer.
Before anything will be printed real-time, either print alarm events or print access
control events has to be set to YES.
30.4. Print data outside timezone
Enables the printer to only operate outside the timezone, and not during it.
YES The printer is only active if the timezone specified is invalid.
NO The printer is only active if the timezone specified is valid.
Press 0 to leave Printer.
Any event that takes place when no data is dumped to the printer will be lost for the
printer. Use “Print history” in the user menu to print these events.
Enable real-time printer has to be set to YES to be able to print events.
30.5. Printer data during timezone
(Print during TZ?)
The printer is only active during the timezone specified unless print data outside timezone
(above) is set to YES. The default timezone is Tz 0 (always valid).