System information
ATS2000/3000/4000/4500 Programming manual
122
No
–
Report Alarm Events to Compute
r
*-Change 0 - Skip
*-Pause, Ph No:
Cmp:
*-Pause, Ph No:
Cbk:
No
–
Report Access Events to Compute
r
*-Change 0 - Skip
End Enter 32 Char. Init modem string
YES Up/Download uses a compatible modem connected to the ATS1801.
NO Up/Download uses the built-in modem.
29.5.1. Enter 32 character init modem string
If Menu 29.5 is set to YES, enter the modem initialization string (You can enter up to 32
characters.) This modem initialization string is sent to a compatible modem on the
ATS1801 (serial printer/computer interface board). The 32 character entry allows for the
following characters: @&/=%+-,;
Press OFF or “*” twice to move onto Menu 29.6
29.6. Report alarms to computer
If alarms have to be reported to a computer.
YES Alarms will be reported using the computer telephone number.
NO No alarms will be reported to the computer.
Press 0 to go directly to Computer telephone number.
29.7. Report access events to
computer
If access control events have to be reported to a computer.
YES Access control events will be reported using the computer telephone number.
NO No access control events will be reported to the computer.
Press 0 to go directly to Computer telephone number..
29.8. Computer telephone number
Holds the telephone number to be dialled by a modem connected to the ATS1801
printer/computer interface to set up a remote up/download connection.
29.9. Up/Download callback telephone
number
Holds the telephone number to be called back to set up a remote up/download
connection. Only used for up/download when dialling into the ATS system.