System information
ATS2000/3000/4000/4500 Programming manual
120
Y
ES
–
Enable Remote Up/Download
*-Change 0 - Skip
No
–
Up/Download i
f
any Area Armed
*-Change 0 - Skip
29. COMPUTER CONNECTION
Holds programming concerning connection to a computer running software package to
program or control the ATS system (e.g. ATS8100).
See also the “Service menu” in the manager’s guide.
When connecting the panel directly via the J18 (on-board RS232 port) or connecting the
panel via the ATS1801 computer/printer interface, it is not necessary to set menus 29.1
to 29.4.
When connecting the panel as a remote connection: via the on-board PSTN dialler or the
ISDN interface (ATS7100) (300 baud) or via a stand-alone ISDN or PSTN modem
connected to the ATS1801 computer / printer interface (4800 baud), at least Menu 29.1
needs to be set to ON.
Every Advisor MASTER control panel has address ‘0’ as the default. When
operating in multi panel configurations with 2 or more panels (only applicable with
TITAN Security System Software) you have to set the corresponding panel
address in Menu 19.29.11: Computer Address.
To ensure optimum security, it is advisable to select the following options for menus 29.1
to 29.4:
Menu 29.1. YES
Menu 29.2. NO
Menu 29.3. NO
Menu 29.4. NO
29.1. Enable remote up/download
Specify if connecting to a remote computer is possible.
YES A remote connection (up/download) is possible.
NO Remote Up/Download is not possible.
Set this option to YES to use menus 29.2 to 29.5.
Press 0 to go directly to Menu 29.8
Before commissioning a system, the Advisor MASTER Control panel must be
provided with a Security Password in Menu 19.29.12.
29.2. Up/Download if any Area Armed
Option 29.1 must set to YES to use this option.