System information
ATS 2000/3000/4000/4500 Programming manual 119
Remote Device: 1-DGP 2-RAS
Device:
28. TO REMOTE DEVICES
Use this option to access the programming menus for 1-Door RAS’s (e.g. ATS1270) or 4-
Door/4-Lift DGP’s (e.g. ATS1250/1260). These remote devices have additional menu’s
that can be accessed via the control panel using this menu.
The remote device has to be:
• Connected to the ATS System Databus
• Addressed as a RAS or DGP with on-board DIP switches
• Programmed to be polled in the menu RAS database (page 42, RAS’s only) or DGP
database (page 49, DGP’s only)
• Programmed with the correct type (DGP’s only) in menu DGP database (page 49).
28.1. Select the device type
To establish a connection to the remote device, select the device type first. The type is
either a RAS (e.g. ATS1270, 1-Door RAS) or a DGP (e.g. ATS1250/1260, 4-Door/4-Lift
DGP).
28.2. Select the device to program
Select the device number to program. The number is the same number as set using the
DIP switches on the device.
For further information on programming the remote device, see the programming
guide for the device.