System information

ATS 2000/3000/4000/4500 Programming manual 115
Output To Timezone
Tz (26-41)
Tz 27 To Follow Output 3
Output No:
22. TIMEZONE TO FOLLOW OUTPUT
Select a timezone to follow an output. When the output is active, the timezone is valid.
Use this option to invalidate alarm groups if certain conditions are not met.
For example:
Prohibit the use of a keypad, unless a keyswitch on a zone is active.
Allow an area to be disarmed only if another area is disarmed before.
The timezones that follow outputs are also referred to as soft timezones. Hard timezones
are valid between a start and end-time.
22.1. Select timezone
Select the timezone to follow the output (timezone 26 – 41 available).
22.1.1. Assign output to follow
Assign the output the timezone has to follow.
When programming door groups, timezones 26 to 41 can only be used with doors
1 to 16.
Doors 17 to 64 are only available on 4-Door DGPs that only recognise timezones 0
to 24.
Timezones 26 to 41 can never be used in door or floor groups.
If the output is inverted, timezone 26 – 41 are valid if the output is not active (the
event flag is not triggered).