For example:
Three alarm groups have been set up:
ALARM GROUP
Option
32 33 34
Area 1, 2 1, 2 1
Alarm group restriction 4 4 4
Timezone 1 2 0
Alternate alarm group 33 34 1 ( = none)
Alarm group restriction 4 is programmed:
Option Standard 1
st
alternate 2
nd
alternate
Timed disarm Area - 2 1
Arm/Reset Area 2 - -
Alarm group 31 is assigned to user 1. Alarm group 32 is assigned to user 2.
Operation:
Timezone 1 is valid:
User 1 will have alarm group 31 with alarm group restriction 4, standard.
Has full control over area 1 and can arm and reset area 2. Timezone 1 does
not effect alarm group 32 (= user 2).
Timezone 1 is invalid but timezone 2 is valid.
User 1 will have the 1st alternate alarm group (32) and alarm group
restriction 4, also 1st alternate. Has full control over area 1. Has timed
disarm for area 2.
User 2 will have alarm group 32 and alarm group restriction 4, standard.
Has full control over area 1 and can arm and reset area 2.
Timezone 1 and 2 are invalid.
User 1 will have the 2nd alternate alarm group (33) and alarm group
restriction 4, also 2nd alternate. Has timed disarm for area 1 and no control
over area 2.
User 2 will have the 1st alternate alarm group (33) and alarm group
restriction 4, also 1st alternate. Has full control over area 1 and no control