System information

ATS2000/3000/4000/4500 Programming manual
100
A
larm Group Restrictions
Restr. No:
Restriction Name: 0352, Cleane
r
Text No:
1,2,3,6,7,
1, Timed Area:
1,2,3,4,5,
1, A/R Area:
9,10,
2, Timed Area:
3. Assign the alarm group restriction to alarm groups in the menu Alarm groups
(page 51).
4. Users cannot operate alarm group restrictions unless the arming station they are
using has the same alarm group restrictions in its alarm group.
15.1. Alarm group restriction number
First select the Alarm group restriction to be programmed (numbered from 1 to 8).
15.1.1. Alarm group restriction name
Select the name of an alarm group restriction from the list of words already held by the
ATS system. These words can be from the standard word library (see Table8 7: Word
library on page 90) or from a list of words that you have programmed yourself
(Programming menu option 10, Program text, on page 89.
Program the alarm group restriction name, using the reference number of the word. The
name should be easily recognisable.
15.1.2. Timed disarm areas
When a user enters a code, the programmed areas are disarmed and a timer starts
running. In order for the function to be enabled, the area(s) listed in this option must also
be listed in the alarm group to which the alarm group restriction is assigned and alarm
system control has to be enabled.
See also Alarm groups on page 51.
15.1.3. Areas to arm/reset
When a user enters a code, the programmed areas are armed or alarms are reset. In
order for the function to be enabled, the area(s) listed in this option must also be listed in
the alarm group to which the alarm group restriction is assigned and alarm system control
has to be enabled.
See also Alarm groups on page 51.
15.1.4. 1
st
Alternate timed disarm area
As explained in Alarm groups on page 51, it is possible to have alternate alarm groups.
The alternate alarm group is used when the original alarm group is not available due to
an invalid timezone.
When an alternate alarm group is active and the alternate alarm group has an alarm
group restriction, the alternate alarm group restriction is used.