Operating instructions

6
5
21 WALK THROUGH ZONES
The factory default is none.
The zone LED's indicate which zones are
walk through during entry.
Use the keys 1 to 8 to select or deselect
walk through zones.
The 0 key deletes all.
Press the full set key to exit.
22 IGNORE ZONE IF FIRST TO ALARM
(Double Knock)
Alarm only if two zones are triggered.
The factory default is none.
The zone LED's indicate which zones are
double knock.
Use the keys 1 to 8 to select or deselect
double knock zones.
The 0 key deletes all.
Press the full set key to exit.
23 AUXILIARY ZONES
Technical alarm. ie. Freezer giving inter-
nal audible and technical alarm channel
of dialler.
The factory default is none.
The zone LED's indicate which zones are
auxiliary zones.
Use the keys 1 to 8 to select or deselect
aux. zones.
The 0 key deletes all.
Press the full set key to exit.
24 24 HOUR ZONES
The factory default is none.
The zone LED's indicate which zones are
24 hour.
Use the keys 1 to 8 to select or deselect
24 hour zones.
The 0 key deletes all.
Press the full set key to exit.
NOTE: If you do not want a 24 hour zone
to be omitted, remove the zone from omit
16 BELL DELAY
1= 0 mins* 2= 1 min 3= 3 mins
4= 4 mins 5= 5 mins 6=6 mins
7=7 mins* 8= 10 mins
Press Full Set to exit
17 FULL SET ZONES
The factory default is all zones active.
The zone LED's indicate which zones are
active in full set.
Use the keys 1 to 8 to select or deselect
zones. The 0 key deletes all.
Press the full set key to exit.
18 PART SET ZONES
The factory default is zones 1 to 4 active.
The zone LED's indicate which zones are
active in part set.
Use the keys 1 to 8 to select or deselect
zones. The 0 key deletes all.
Press the full set key to exit.
19 OMIT PERMIT ZONES
(The zones that the user is allowed to omit)
The factory default is all zones allowed to
be omitted except zone 1.
The zone LED's indicate which zones are
allowed to be omitted.
Use the keys 1 to 8 to select or deselect
zones. The 0 key deletes all.
Press the full set key to exit.
2O FINAL EXIT ZONES
(Zones that start the entry time)
The factory default is zone 1 only.
The zone LED's indicate which zones will
start the entry timer.
Use the keys 1 to 8 to select or deselect
zones.
The 0 key deletes all.
Press the full set key to exit.
permit via program No.19.
25 SOAK TEST ZONES
The factory default is
none.
The zone LED's indicate which zones are
on soak test.
Use the keys 1 to 8 to select or deselect
soak test zones.
The 0 key deletes all.
Press the full set key to exit.
26 CHIME ZONES
The factory default is none.
The zone LED's indicate which zones are
on chime.
Use the keys 1 to 8 to select or deselect
chime zones.
The 0 key deletes all.
Press the full set key to exit.
27 P.A. SILENT / AUDIBLE The
factory default is audible.
1= Silent O= Audible *
Press the full set key to exit.
28 DOUBLE BUTTON P.A.
(To activate a panic from a remote con-
trol, both PA & OFF buttons must be
pressed simultaneously)
The factory default is single button.
1= Double O= Single*
Press the full set key to exit.
29 SILENT PART SET
1= Silent O= Audible*
Press the full set key to exit.
30 UPSTAIRS / DOWNSTAIRS
This option tells the panel to accept part
set button as a separate alarm system.
eg. The Part Set button becomes the
alarm system in the flat & the Full set
button is a separate alarm system in
the office. In this mode the user can
set either one or the other, or both
systems by selection when arming.
1 = Select Upstairs/Downstairs mode.
O= Normal Part / Full set mode.*
Press the full set key to exit.
31 8 SECOND STROBE WHEN FINAL
SET AND UNSET
If selected the strobe output operates
for 8 seconds at the moment the panel
is full set. i.e. when the exit timer
terminates.
The strobe also operates for 8 sec-
onds when the panel is Unset from
Full Set.
1 = 8 sec. Strobe 0 = No 8 second
strobe
Press the full set key to exit.
32 COURTESY STROBE IN FULL SET
ENTRY / EXIT
If selected the strobe output terminal
8 operates when Full setting the panel.
The strobe output also operates for
the entry time when unsetting from
Full Set.
(If a mains relay was connected via
this output a mains courtesy light could
be switched on by disarming from
outside with a remote control.)
1= Courtesy strobe on O=off*
Press the full set key to exit.
33 WALK THROUGH ZONES BE-
COME FINAL EXIT IN PART SET
To prevent false alarms in part set it is
often useful to make walk through
zones initiate the entry timer.